GBR-Gai
High Resolution | Automatic Tracking System | Convenient Animal Retrieval
Product Description

The GBR-Gai High-Resolution Single (Multi)-Channel Gait Analysis System is designed for precise motor function assessment in small animals. During testing, animals are placed on a transparent walkway and walk spontaneously from one end to the other. The system utilizes footprint light refraction technology and a high-speed bottom camera to capture detailed paw contact patterns in real time, while a side-view camera simultaneously records joint movements. Using deep learning and image processing algorithms, the system automatically identifies and analyzes complete gait cycles, quantifying the impact of disease models such as arthritis and nerve injury on motor function. It provides objective, high-precision data for neuroscience, orthopedics, rehabilitation medicine, and drug discovery.

Consistency Evaluation of Photoacoustic Imaging and Histology
Lei P et al., J Biophotonics. 2020 Dec;13(12):e202000162. DOI:10.1002/jbio.202000162.



Key Features & Advantages
1. High-Resolution Imaging for Fine Detail Capture
Equipped with high-sensitivity cameras, the system supports video capture at 1080p @ 120 fps (up to 720p @ 240 fps), clearly recording subtle paw contours, pressure distribution, and joint angle variations, ensuring data accuracy and depth.
2. Automated Real-Time Tracking
An integrated automatic tracking system (tracking range: 120 cm) uses a controller and stepper motor to follow the animal's movement along the walkway, keeping the subject in the optimal field of view for fully automated data acquisition.
3. Dual-View Synchronized Analysis
The system integrates ventral footprint recording with lateral joint tracking:
Ventral view: Captures paw area, pressure distribution, and step sequence.
Lateral view: Simultaneously records joint angles (knee, ankle) and limb swing dynamics.
This dual-view fusion provides a comprehensive assessment of gait and postural coordination.
4. Convenient Animal Retrieval System
A dedicated retrieval mechanism at the end of the walkway allows animals to automatically and gently return to the starting area after each trial, significantly simplifying procedures and reducing stress and human interference.
5. Enclosed Camera & Lighting System
The system features a shielded chamber with integrated dual-color LED lighting (red/green). The green LED light undergoes total internal reflection within the glass plate and scatters only when the paw contacts the surface, creating high-contrast footprints without the need for staining or labeling. This design ensures stable operation under any ambient lighting condition.
6. Adjustable Walkway Width
The walkway is 150 cm in length, with width adjustable between 4 cm and 8 cm to accommodate different rodent sizes (mice and rats), ensuring natural and comfortable movement.
Product Parameters
|
GBR-Gai Technical parameters |
|
|
Product size |
175*35*55cm |
|
Footprint optical refraction walkway system |
Material: tempered glass |
|
Length 150cm |
|
|
Width adjustment range 4cm/8cm |
|
|
Red LED background light |
|
|
Reflected light source green LED |
|
|
Automatic tracking system |
Tracking range: 120cm, use the controller to track the movement in real time |
|
The position of the object and drive the stepper motor to track |
|
|
Shooting system |
Video quality: 1080p, 120fps, up to 720p, 240fps |
|
Software Analysis |
Individual footprint data extraction |
|
Multi-footprint data hotspot analysis |
|
|
Footstep area recognition results |
|
|
Exercise speed judgment and exercise status classification |
|
|
Other analytical metrics |
|||
|
Braking percentage |
Swing duration |
Stride length |
Touchdown Percentage |
|
Touchdown percentage |
Stride length variability |
Footstep angle |
Ground contact braking percentage |
|
Touchdown width |
Stride frequency |
Swing percentage |
Duration of advancement |
|
Braking duration |
Touchdown time |
Stride length |
Percentage of advancement |
|
Swing touch ratio |
|
|
|
Applications
1. Neuroscience Research
Nerve Injury & Repair: Evaluate functional recovery after spinal cord injury, peripheral nerve injury, or traumatic brain injury.
Neurodegenerative Diseases: Detect motor deficits in models of Parkinson's disease (PD), Alzheimer's disease (AD), and ataxia.
Neurodevelopment: Study gait maturation to understand motor control development.
2. Orthopedics & Muscle Research
Arthritis Models: Quantify joint dysfunction and pain-related gait changes in osteoarthritis and rheumatoid arthritis.
Muscle Disorders: Assess motor impairments in muscular dystrophy and muscle contusion.
3. Rehabilitation Medicine
Therapy Evaluation: Objectively measure the efficacy of physical therapy and rehabilitation training.
Assistive Device Optimization: Assess and refine prostheses and orthoses based on gait parameters.
4. Drug Discovery & Evaluation
Pharmacodynamic Assessment: Objectively evaluate analgesic, anesthetic, and neurotrophic drugs on motor function.
Side Effect Monitoring: Detect early signs of ataxia or tremor during preclinical safety profiling.
5. Behavioral & Comparative Biology
Behavioral Strategy Analysis: Study gait adaptations under different environmental or physiological states.
Cross-Species Comparisons: Explore evolutionary and ecological adaptations through gait differences.
Hot Tags: high-resolution single (multi)-channel gait analysis system, China high-resolution single (multi)-channel gait analysis system manufacturers, suppliers, factory, Animal Gait Intelligent Analysis System, behavioral analysis of annelid animals, animal behavior in tundra habitats, analysis of animal web building behavior, behavioral analysis of kinorhynch animals, animal behavior during imprinting