GBR-Gait
Adjustable Speed | Customizable Dimensions | Enclosed Camera System
Product Description
The GBR-Gait Treadmill-Based Gait Analysis System is an automated platform designed for preclinical motor function assessment. Animals are placed on a motorized treadmill, where they are prompted to walk or run as the belt moves. During this process, two high-resolution cameras positioned at perpendicular angles simultaneously record ventral footprints and lateral joint movements. The system employs footprint light refraction technology and deep learning-based algorithms to automatically detect and analyze complete gait cycles, quantifying the impact of disease models such as arthritis and nerve injury on motor function. It delivers objective, reproducible data for drug screening and mechanistic research.



Key Features & Advantages
1. Dual-View Synchronized Analysis for Comprehensive Data
The system integrates ventral footprint recording with lateral joint tracking. The bottom view captures detailed paw contact patterns, pressure distribution, and step sequence; the side view simultaneously records joint angles (elbow, wrist, knee, ankle) and limb swing dynamics. This two-dimensional fusion reveals subtle postural and coordination changes that footprint data alone cannot provide, enabling a more thorough motor function assessment.
2. Adjustable Speed and Flexible Modes
Treadmill speed is continuously adjustable up to 2.5 m/s, accommodating protocols from slow walking to rapid running. The system supports both active (voluntary) and passive (belt-driven) locomotion modes, making it suitable for various disease stages (e.g., acute spinal cord injury) and research aims (e.g., fatigue induction).
3. Customizable Runway Dimensions for Multiple Species
Runway length and width can be tailored to the animal's body size. Currently validated for:
Mice: width ~5–10 cm, length ~30–50 cm
Rats: width ~10–15 cm, length ~50–80 cm
Guinea pigs, rabbits, and larger species upon request
This customization ensures natural, stress-free movement, which is critical for accurate gait data.
4. Enclosed Camera & Lighting System for Stable Imaging
The system features a shielded chamber with integrated LED lighting (red/green dual-wavelength). The green LED light undergoes total internal reflection within a glass plate; it scatters only when the animal's paw contacts the surface, creating high-contrast footprints captured by the below-mounted high-speed camera. This design eliminates ambient light interference and enables clear imaging even with dark-furred animals, without the need for staining or labeling.
Product Parameters
|
GBR-Gait Technical parameters |
|
|
Product size |
55*40*65cm |
|
Footprint optical refraction runway system |
Length 50cm, can be customized |
|
Material: PU |
|
|
Red LED background light |
|
|
Reflected light source green LED |
|
|
Shooting system |
Bottom and side shots are bi-directional, allowing simultaneous analysis of experiments |
|
Gait and posture of the animal |
|
|
Video quality: 1080p.120fps, up to 720p, 240fps |
|
|
Lateral analysis |
Changes in knee and ankle angles |
|
Changes in limb swing |
|
|
Relative swing amplitude of limbs, etc |
|
|
Analysis below |
Individual footprint data extraction |
|
Multi-footprint data hotspot analysis |
|
|
Exercise speed judgment and exercise status classification |
|
|
Footstep area recognition results |
|
Data Outputs
The system automatically computes and exports the following parameter categories:
| Analysis Dimension | Specific Parameters |
|---|---|
| Footprint Parameters | Swing phase, stance phase, stride length, step frequency, footprint area & pressure, normal gait ratio, stance-swing ratio, sciatic/tibial/fibular nerve indices |
| Joint Parameters | Mean/max/min joint angles (elbow, wrist, knee, ankle), range of motion, joint height & vertical displacement |
| Visualization Outputs | Footprint sequence diagrams, maximum projection maps, 2D/3D pressure distribution, joint angle time-series graphs, movement trajectories |
Applications
1. Neuroscience
Nerve Injury Models: Evaluate functional recovery after spinal cord injury, peripheral nerve injury, or traumatic brain injury.
Neurodegenerative Diseases: Quantify motor deficits in models of Parkinson's disease (PD), Alzheimer's disease (AD), ataxia, and stroke.
Neurodevelopment: Study gait maturation in juvenile animals to understand critical stages of motor control development.
2. Orthopedics & Muscle Research
Arthritis Models: Assess joint function and pain-related gait changes in osteoarthritis and rheumatoid arthritis.
Muscle Disorders: Evaluate motor impairments in muscular dystrophy, muscle contusion, and related conditions.
3. Rehabilitation Medicine
Therapy Evaluation: Objectively measure the efficacy of physical therapy and rehabilitation training.
Assistive Device Optimization: Assess and refine the fit of prostheses and orthoses based on gait parameters.
4. Drug Discovery & Evaluation
Pharmacodynamic Assessment: Objectively evaluate analgesic, anesthetic, and neurotrophic drugs on motor function.
Side Effect Monitoring: Detect early signs of ataxia, tremor, or other motor side effects during preclinical safety profiling.
5. Behavioral & Comparative Biology
Behavioral Strategy Analysis: Study gait adaptations under different environmental or physiological states (e.g., stress, foraging).
Cross-Species Comparisons: Compare gait patterns across species to explore evolutionary and ecological adaptations.
Hot Tags: animal treadmill gait analysis system, China animal treadmill gait analysis system manufacturers, suppliers, factory, High Resolution Animal Gait Analysis System, animal behavior in riverine habitats, Animal Behavior Analyzer, animal behavior analysis, animal behavior in archipelago habitats, monitoring animal pseudopod extension behavior
