Animal Treadmill Gait Analysis System

Animal Treadmill Gait Analysis System
Details:
GBR-Gait
Adjustable speed, Customized length and width, Enclosed camera
Send Inquiry
Description
Send Inquiry

GBR-Gait
Adjustable Speed | Customizable Dimensions | Enclosed Camera System

 

Product Description

 

The GBR-Gait Treadmill-Based Gait Analysis System is an automated platform designed for preclinical motor function assessment. Animals are placed on a motorized treadmill, where they are prompted to walk or run as the belt moves. During this process, two high-resolution cameras positioned at perpendicular angles simultaneously record ventral footprints and lateral joint movements. The system employs footprint light refraction technology and deep learning-based algorithms to automatically detect and analyze complete gait cycles, quantifying the impact of disease models such as arthritis and nerve injury on motor function. It delivers objective, reproducible data for drug screening and mechanistic research.

 

product-250-250
Mouse footprint data extraction
product-250-250
Multi-footprint data hotspot analysis
product-250-250
Lateral joint analysis

 

Key Features & Advantages

 

1. Dual-View Synchronized Analysis for Comprehensive Data
The system integrates ventral footprint recording with lateral joint tracking. The bottom view captures detailed paw contact patterns, pressure distribution, and step sequence; the side view simultaneously records joint angles (elbow, wrist, knee, ankle) and limb swing dynamics. This two-dimensional fusion reveals subtle postural and coordination changes that footprint data alone cannot provide, enabling a more thorough motor function assessment.

 

2. Adjustable Speed and Flexible Modes
Treadmill speed is continuously adjustable up to 2.5 m/s, accommodating protocols from slow walking to rapid running. The system supports both active (voluntary) and passive (belt-driven) locomotion modes, making it suitable for various disease stages (e.g., acute spinal cord injury) and research aims (e.g., fatigue induction).

 

3. Customizable Runway Dimensions for Multiple Species
Runway length and width can be tailored to the animal's body size. Currently validated for:

Mice: width ~5–10 cm, length ~30–50 cm

Rats: width ~10–15 cm, length ~50–80 cm

Guinea pigs, rabbits, and larger species upon request

This customization ensures natural, stress-free movement, which is critical for accurate gait data.

 

4. Enclosed Camera & Lighting System for Stable Imaging
The system features a shielded chamber with integrated LED lighting (red/green dual-wavelength). The green LED light undergoes total internal reflection within a glass plate; it scatters only when the animal's paw contacts the surface, creating high-contrast footprints captured by the below-mounted high-speed camera. This design eliminates ambient light interference and enables clear imaging even with dark-furred animals, without the need for staining or labeling.

 

Product Parameters

 

GBR-Gait Technical parameters

Product size

55*40*65cm

Footprint optical refraction runway system

Length 50cm, can be customized

Material: PU

Red LED background light

 

Reflected light source green LED

Shooting system

Bottom and side shots are bi-directional, allowing simultaneous analysis of experiments

Gait and posture of the animal

Video quality: 1080p.120fps, up to 720p, 240fps

Lateral analysis

Changes in knee and ankle angles

Changes in limb swing

Relative swing amplitude of limbs, etc

Analysis below

Individual footprint data extraction

Multi-footprint data hotspot analysis

Exercise speed judgment and exercise status classification

Footstep area recognition results

 

 

Data Outputs

 

The system automatically computes and exports the following parameter categories:

Analysis Dimension Specific Parameters
Footprint Parameters Swing phase, stance phase, stride length, step frequency, footprint area & pressure, normal gait ratio, stance-swing ratio, sciatic/tibial/fibular nerve indices
Joint Parameters Mean/max/min joint angles (elbow, wrist, knee, ankle), range of motion, joint height & vertical displacement
Visualization Outputs Footprint sequence diagrams, maximum projection maps, 2D/3D pressure distribution, joint angle time-series graphs, movement trajectories

 

 

Applications

 

1. Neuroscience

Nerve Injury Models: Evaluate functional recovery after spinal cord injury, peripheral nerve injury, or traumatic brain injury.

Neurodegenerative Diseases: Quantify motor deficits in models of Parkinson's disease (PD), Alzheimer's disease (AD), ataxia, and stroke.

Neurodevelopment: Study gait maturation in juvenile animals to understand critical stages of motor control development.

 

2. Orthopedics & Muscle Research

Arthritis Models: Assess joint function and pain-related gait changes in osteoarthritis and rheumatoid arthritis.

Muscle Disorders: Evaluate motor impairments in muscular dystrophy, muscle contusion, and related conditions.

 

3. Rehabilitation Medicine

Therapy Evaluation: Objectively measure the efficacy of physical therapy and rehabilitation training.

Assistive Device Optimization: Assess and refine the fit of prostheses and orthoses based on gait parameters.

 

4. Drug Discovery & Evaluation

Pharmacodynamic Assessment: Objectively evaluate analgesic, anesthetic, and neurotrophic drugs on motor function.

Side Effect Monitoring: Detect early signs of ataxia, tremor, or other motor side effects during preclinical safety profiling.

 

5. Behavioral & Comparative Biology

Behavioral Strategy Analysis: Study gait adaptations under different environmental or physiological states (e.g., stress, foraging).

Cross-Species Comparisons: Compare gait patterns across species to explore evolutionary and ecological adaptations.

 

Hot Tags: animal treadmill gait analysis system, China animal treadmill gait analysis system manufacturers, suppliers, factory, High Resolution Animal Gait Analysis System, animal behavior in riverine habitats, Animal Behavior Analyzer, animal behavior analysis, animal behavior in archipelago habitats, monitoring animal pseudopod extension behavior

Send Inquiry