Multimodal Endoscopic Imaging System

Multimodal Endoscopic Imaging System
Details:
Animal Multi-modal Microcatheter Endoscopy GPA-US-10, GUS-2D/3D, GOCT-OCT, GOCT-US-10 Multi-modal (Photoacoustic, Ultrasonic, OCT) in vivo imaging Photoacoustic lateral direction Resolution down to 15μm, OCT lateral direction Resolution down to 8μm, Ultrasound imaging depth up to 30mm 3D Merged Imaging
Send Inquiry
Description
Send Inquiry

Animal Multi-modal Microcatheter Endoscopy GPA-US-10, GUS-2D/3D, GOCT-OCT, GOCT-US-10 lMulti-modal (Photoacoustic, Ultrasonic, OCT) in vivo imaging lPhotoacoustic lateral direction Resolution down to 15μm, OCT lateral direction Resolution down to 8μm, Ultrasound imaging depth up to 30mm 3D Merged Imaging

 

Product Advantages

 

Innovative multimodal endoscope

In vivo imaging; larger depth; detect mucosal lesions and structural lesions.

 

Multimodal endoscopy

Higher resolution and deeper penetration

 

Penetration:

The whole biological tube wall

 

Resolution:

Photoacoustic transverse≤15μm, axial≤65μm

Ultrasound: axial:≤65μm

OCT: transverse≤20μm,axial≤8μm

 

Highlights:

OCT Imaging

Ultrasound imaging

Photoacoustic imaging

Structural imaging

Functional imaging

High resolution, deep penetration, three-dimensional imaging, specific imaging

Structural lesions, mucosal lesions

 

product-132-151
product-149-151
product-136-150
product-149-150

Penetration: The full thickness of the biological tube wall.

Resolution: Increased by 20 times.

product-342-97
product-342-98
product-342-99

 

Applications

 

Meet the endoscopic needs of various experimental animals

Endoscopic experiments on rats,mice,rabbits and pigs

product-217-164
product-217-164
product-217-164
product-422-144
Vascular network by photoacoustic imaging
product-422-144
Photoacoustic depth tomography
product-422-144
Photoacoustic ultrasound 3D imaging
product-338-239
Photoacoustic ultrasound 2D cross-sectional imaging
product-338-239
Cross-sectional imaging
product-338-239
Photoacoustic 3D tunnel perspective

 

Product Description

 

Photoacoustic multi-modal imaging system combines optical imaging and acoustic imaging techniques to provide high-resolution images of biological tissues at different depths. This technology can be applied to various fields, such as cancer diagnosis, brain imaging, and vascular imaging. The photoacoustic multi-modal imaging system has advantages such as non-invasive, real-time imaging, and low-cost, which makes it a promising tool for medical research and clinical applications.

 

Product Parameters

 

There are four models of the photoacoustic multi-modal imaging system. Please check the parameters as follows.

 

Product Model

GPA-US

GUS

GOCT-US

G0CT

Imaging modality

PAE&US

US

OCT&US

OCT

Application

Cardiovascular, digestive system, otolaryngology

Digestive system, ear, nose and throat, urinary system

Cardiovascular, Digestive System, ENT

Cardiovascular, Digestive System, Ear, Nose and Throat, Cranial Nervous System

Scan angle/ Retraction distance

360°/80 mm

360°/40 mm

360°/ 80 mm

360°/80 mm

Scan mode

2D/3D

2D/3D

2D/3D

2D/3D

Probe frequency

12/20 MHz

12/20 MHz

12/20 MHz

/

Imaging speed

30 fps

30 fps

30 fps

100 fps

Resolution

(PAE) transverse≤15μm,axial≤65μm (US)axial≤65μm

axial:≤65μm

(OCT) transverse≤20um,axial≤8um (US)axial≤65μm

transverse≤20um, axial≤8 um

Imaging depth

PAE≥3mm US≥30 mm

≥30 mm

OCT≥ 3mm US≥30 mm

≥3mm

Catheter diameter

1.0/2.5 mm

0.7/2.1/2.5 mm

1.0/2.5 mm

1.0 mm

Tube selection

Standard, balloon, guidewire

Standard, balloon, guidewire

Standard, balloon, guidewire

Standard, balloon, guidewire

 

Catheter Model

Outer Diameter (mm)

Frequency (MHz) - Wavelength (nm)

Length (mm)

Features

Imaging Modalities

UE-s-2D

0.7/2.1/2.5

12/20/30

2100

Single frequency B-mode imaging

Ultrasound

UE-d-2D

2.5

12-20/12-30

2100

Single frequency B-mode imaging

Ultrasound

UE-BS20-2D

1/2.1

12/20/30

2100

Guidewire-compatible B-mode imaging

Ultrasound

UE-G20-2D

2.5

12/20/30

2100

Balloon catheter B-mode imaging

Ultrasound

US-DP12

2.1/2.5

12/20/30

2100

Balloon catheter B-mode imaging

Ultrasound

OCT-DP

1

1310

2100

B-mode imaging

OCT

 

OCTUE-DP20

1/2.5

20-1310

2100

Dual-modalities 2D and 3D biplanar imaging

Ultrasound + OCT

PAUE-DP20

1/2.5

20-532/1064

2100

Dual-modalities 2D and 3D biplanar imaging

Photoacoustic + Ultrasound

 

Imaging Examples

 

product-267-320

 

Scanning and imaging of the large lumens (such as the esophagus, trachea, intestine, stomach wall, etc.) with a balloon catheter endoscope.

 

Ultrasound imaging of the colorectum in living pigs.

product-334-313

product-264-145

 

Scanning and imaging with a standard catheter endoscope.

Optical Coherence Tomography (OCT) imaging of the coronary arteries of the porcine heart.

 

3D Optical Coherence Tomography (OCT) images of the coronary arteries of the porcine heart.

product-335-111

product-334-100

 

Hot Tags: multimodal endoscopic imaging system, China multimodal endoscopic imaging system manufacturers, suppliers, factory, Fluorescence Slide Scanning System, Brightfield Slide Scanner, Multimodal Photoacoustic Small Animal Imager, Digital Pathology Scanner GScan 40, Automatic Pathological Section Scanning System, Multimodal Small Animal Microscopic Imaging System

Send Inquiry